The Stakgard continuous dust monitor uses the well-proven tribo-electric effect to directly measure mass particulate concentration by sensing the
frictional charge created when particles collide with a conductor. The advanced electronics of the StakGard detect this signal and present it to the operator via a unique modulating LED display.

StakGard incorporates an adjustable damping system that increases the response time of the alarm and analogue circuits and so prevents false alarms.

Key Featuresdust-emission-monitoring-stackgard

  • Robust, reliable & suitable for all particulates
  • Easy installation, low maintenance
  • Well-proven technology, accurate sensing method
  • Adaptable; suitable for virtually all dust collectors
  • Wide range of duct sizes from 250mm to 2m
  • Direct sensing method; actual particulate concentration

Feature

Specification

Operating Range 0.1 to 2500mg/m3
Duct Diameter 250mm to 2m
Ambient Temperature -20°C to +70°C
Power supply 48V DC supplied from Power Supply Unit (PSU)
Construction aluminium casting, weatherproof to IP67 (NEMA 4)
Analogue outputs 4-20mA isolated (linear)
Logic Outputs single pole changeover, 10A/240V
Serial Data RS232

Lang Filetype Document Size
English Adobe_Acrobat_Pro_PDF StakGard Datasheet 400kb

Download will be instantly be availble after form submission.

Send StakGard Product Enquiry

 Please call to discuss our requirements

Related Tunnel Analysers

GCEM 40 Series Gas Analyser
The GCEM4000 is a multi-channel flue gas analyser that uses Non-Dispersive Infrared Absorption (NDIR) technology.
View Product
VCEM5000/5100 Flow Monitor
The VCEM5000/5100 provides non-contact measurement of gas velocity using a time-delay correlation of flue gas infrared emissions received by two detectors spaced a fixed distance apart.
View Product