{"id":4912,"date":"2022-12-23T09:01:35","date_gmt":"2022-12-23T09:01:35","guid":{"rendered":"https:\/\/www.codel.co.uk\/?p=4912"},"modified":"2026-07-16T15:02:08","modified_gmt":"2026-07-16T15:02:08","slug":"hcl-so2-absorption-efficiency","status":"publish","type":"post","link":"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/","title":{"rendered":"HCL, SO2 Absorption Efficiency"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4912\" class=\"elementor elementor-4912\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4384e4c elementor-section-full_width elementor-section-stretched elementor-section-height-default elementor-section-height-default\" data-id=\"4384e4c\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-34700bcc\" data-id=\"34700bcc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-25b0936d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"25b0936d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-inner-column elementor-element elementor-element-12de8929\" data-id=\"12de8929\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5827043e elementor-widget elementor-widget-text-editor\" data-id=\"5827043e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Worldwide Support<\/strong><br \/>Over 25 distributors and support centres worldwide<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-inner-column elementor-element elementor-element-39f9635b\" data-id=\"39f9635b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7f1dc733 elementor-widget elementor-widget-text-editor\" data-id=\"7f1dc733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Flexible maintenance contracts<\/strong><br \/>Tailor made plant specific contracts with 24Hr Support<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-inner-column elementor-element elementor-element-4161627f\" data-id=\"4161627f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ab7b76f elementor-widget elementor-widget-text-editor\" data-id=\"ab7b76f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>30 years experience<\/strong><br \/>Developing, manufacturing and installing<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2be072d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2be072d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f27add2\" data-id=\"f27add2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f52d365 elementor-widget elementor-widget-heading\" data-id=\"f52d365\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">The HCL, SO2 Absorption Efficiency in a Dry Scrubber Process. (RAW GAS)<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-782eb4f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"782eb4f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-769675f\" data-id=\"769675f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2526cd0 elementor-widget elementor-widget-heading\" data-id=\"2526cd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">HCL, SO2 Absorption Efficiency:\n\n<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99c2f72 elementor-widget elementor-widget-text-editor\" data-id=\"99c2f72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex-shrink-0 flex flex-col relative items-end\"><div><div class=\"pt-0.5 juice:pt-0\"><div class=\"gizmo-bot-avatar flex h-6 w-6 items-center justify-center overflow-hidden rounded-full juice:h-8 juice:w-8\"><div class=\"relative p-1 rounded-sm flex items-center justify-center bg-token-main-surface-primary text-token-text-primary h-8 w-8\"><span style=\"color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\">The emission of acidic gases from various sources is one of the main environmental concerns. To address this issue, effective cleaning processes, such as absorbers, are commonly used to minimize the release of these gases into the atmosphere.<\/span><\/div><div class=\"relative p-1 rounded-sm flex items-center justify-center bg-token-main-surface-primary text-token-text-primary h-8 w-8\"><span style=\"color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\">\u00a0<\/span><\/div><\/div><\/div><\/div><\/div><div class=\"group\/conversation-turn relative flex w-full min-w-0 flex-col agent-turn\"><div class=\"flex-col gap-1 md:gap-3\"><div class=\"flex flex-grow flex-col max-w-full\"><div class=\"min-h-[20px] text-message flex flex-col items-start whitespace-pre-wrap break-words [.text-message+&amp;]:mt-5 juice:w-full juice:items-end overflow-x-auto gap-2\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"44136d39-0979-4062-b7cb-9425f9572c91\"><div class=\"flex w-full flex-col gap-1 juice:empty:hidden juice:first:pt-[3px]\"><div class=\"markdown prose w-full break-words dark:prose-invert light\"><p>In order to achieve the optimum efficiency of an absorber, precise control of the entire process is required. This control begins with fuel mixing and extends to the measurements that provide crucial feedback for regulation. For instance, burning fuel in Waste to Energy plants and Biomass plants produces HCl and SO2 in the flue gas, which are subsequently removed in an abatement section. The dosage of sorbent is then optimized based on the actual measurement of the concentrations of HCl and SO2 gases upstream of the absorber.<\/p><p>\u00a0<\/p><p>Furthermore, in Waste to Energy plants, fuel can be mixed in a manner that results in the combustion generating HCl in the flue gas at concentration levels that enhance SO2 absorption in a scrubber. This method ultimately leads to higher overall efficiency of the absorber.<\/p><p>\u00a0<\/p><p>Additionally, the CODEL GCEM 40 in-situ analyzer, which measures SO2, HCl, NO, CO, CO2, and H2O, is gaining increased attention as a suitable instrument for measuring acidic gases upstream of the absorber. Many Waste to Energy and Biomass plants across Europe, including those in Finland, Germany, the UK, Lithuania, Serbia, France, the Czech Republic, and Poland, are already using it for process control.<\/p><p>\u00a0<\/p><\/div><\/div><\/div><\/div><\/div><\/div><p>Key advantages that have been appreciated by customers in this application are:<\/p><ul><li>Reliability in harsh raw gas environment<\/li><li>Low maintenance and cost of ownership<\/li><li>In-situ method measurement on wet basis<\/li><li>Representative measurement that is not prone to sample dilution or acid gases loss.<\/li><li>Combined SO2, HCL, H2O, temperature, pressure measurements in single analyser for optimum accuracy.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b59b570 elementor-widget elementor-widget-heading\" data-id=\"b59b570\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Recently Commissioned:<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c8db57 elementor-widget elementor-widget-text-editor\" data-id=\"5c8db57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>At the end of October 2022 a Codel engineer successfully commissioned another GCEM 40 SO2, HCL, H2O, CO2 on scrubber inlet application. This was in Finland in one of the many paper factories in this country, on a BFB boiler that burns mixed fuels, bark, clean recycled wood, sludge, and SRF (Solid Recovered Fuel).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d198394 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d198394\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0cd7f6f\" data-id=\"0cd7f6f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d74af21 elementor-widget elementor-widget-image\" data-id=\"d74af21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.codel.co.uk\/wp-content\/uploads\/elementor\/thumbs\/HCL_SO2-Absorption-scaled-q9atwrd3xkjrhths626zlviyrz8g60xio1wq8hdzcw.jpg\" title=\"HCL_SO2 Absorption\" alt=\"HCL, SO2 Absorption\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Worldwide SupportOver 25 distributors and support centres worldwide Flexible maintenance contractsTailor made plant specific contracts with 24Hr Support 30 years experienceDeveloping, manufacturing and installing The HCL, SO2 Absorption Efficiency in a Dry Scrubber Process. (RAW GAS) HCL, SO2 Absorption Efficiency: The emission of acidic gases from various sources is one of the main environmental concerns. &#8230; <a title=\"HCL, SO2 Absorption Efficiency\" class=\"read-more\" href=\"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/\" aria-label=\"Read more about HCL, SO2 Absorption Efficiency\">\u0427\u0438\u0442\u0430\u0442\u044c \u0434\u0430\u043b\u0435\u0435<\/a><\/p>","protected":false},"author":2,"featured_media":9244,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4912","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>HCL, SO2 Absorption Efficiency - CODEL International LTD<\/title>\n<meta name=\"description\" content=\"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HCL, SO2 Absorption Efficiency\" \/>\n<meta property=\"og:description\" content=\"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/\" \/>\n<meta property=\"og:site_name\" content=\"CODEL International LTD\" \/>\n<meta property=\"article:published_time\" content=\"2022-12-23T09:01:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-16T15:02:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Teresa Shirley\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"Teresa Shirley\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/\"},\"author\":{\"name\":\"Teresa Shirley\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#\\\/schema\\\/person\\\/317a00a7d8844a6cb1b6a2d04f99b6b6\"},\"headline\":\"HCL, SO2 Absorption Efficiency\",\"datePublished\":\"2022-12-23T09:01:35+00:00\",\"dateModified\":\"2026-07-16T15:02:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/\"},\"wordCount\":390,\"publisher\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Copy-of-TT-Blog-Thumbnail-3.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/\",\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/\",\"name\":\"HCL, SO2 Absorption Efficiency - CODEL International LTD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Copy-of-TT-Blog-Thumbnail-3.jpg\",\"datePublished\":\"2022-12-23T09:01:35+00:00\",\"dateModified\":\"2026-07-16T15:02:08+00:00\",\"description\":\"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Copy-of-TT-Blog-Thumbnail-3.jpg\",\"contentUrl\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Copy-of-TT-Blog-Thumbnail-3.jpg\",\"width\":1200,\"height\":628},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/hcl-so2-absorption-efficiency\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.codel.co.uk\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HCL, SO2 Absorption Efficiency\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#website\",\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/\",\"name\":\"CODEL International LTD\",\"description\":\"Codel International LTD -  Stack, Process Control and Tunnel Emission Monitors\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.codel.co.uk\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#organization\",\"name\":\"CODEL International LTD\",\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2021\\\/01\\\/CODEL-international-ltd-logo-1.png\",\"contentUrl\":\"https:\\\/\\\/www.codel.co.uk\\\/wp-content\\\/uploads\\\/2021\\\/01\\\/CODEL-international-ltd-logo-1.png\",\"width\":300,\"height\":78,\"caption\":\"CODEL International LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.codel.co.uk\\\/#\\\/schema\\\/person\\\/317a00a7d8844a6cb1b6a2d04f99b6b6\",\"name\":\"Teresa Shirley\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g\",\"caption\":\"Teresa Shirley\"},\"sameAs\":[\"https:\\\/\\\/www.codel.co.uk\"],\"url\":\"https:\\\/\\\/www.codel.co.uk\\\/ru\\\/author\\\/teresashirley\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HCL, SO2 Absorption Efficiency - CODEL International LTD","description":"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/","og_locale":"ru_RU","og_type":"article","og_title":"HCL, SO2 Absorption Efficiency","og_description":"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance","og_url":"https:\/\/www.codel.co.uk\/ru\/hcl-so2-absorption-efficiency\/","og_site_name":"CODEL International LTD","article_published_time":"2022-12-23T09:01:35+00:00","article_modified_time":"2026-07-16T15:02:08+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg","type":"image\/jpeg"}],"author":"Teresa Shirley","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"Teresa Shirley","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"3 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#article","isPartOf":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/"},"author":{"name":"Teresa Shirley","@id":"https:\/\/www.codel.co.uk\/#\/schema\/person\/317a00a7d8844a6cb1b6a2d04f99b6b6"},"headline":"HCL, SO2 Absorption Efficiency","datePublished":"2022-12-23T09:01:35+00:00","dateModified":"2026-07-16T15:02:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/"},"wordCount":390,"publisher":{"@id":"https:\/\/www.codel.co.uk\/#organization"},"image":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#primaryimage"},"thumbnailUrl":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg","articleSection":["Uncategorized"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/","url":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/","name":"HCL, SO2 Absorption Efficiency - CODEL International LTD","isPartOf":{"@id":"https:\/\/www.codel.co.uk\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#primaryimage"},"image":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#primaryimage"},"thumbnailUrl":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg","datePublished":"2022-12-23T09:01:35+00:00","dateModified":"2026-07-16T15:02:08+00:00","description":"Improve dry scrubber efficiency with accurate HCl and SO\u2082 measurement in raw flue gas. Discover how in-situ analysis optimises absorber control and emissions compliance","breadcrumb":{"@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#primaryimage","url":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg","contentUrl":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2022\/12\/Copy-of-TT-Blog-Thumbnail-3.jpg","width":1200,"height":628},{"@type":"BreadcrumbList","@id":"https:\/\/www.codel.co.uk\/hcl-so2-absorption-efficiency\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.codel.co.uk\/"},{"@type":"ListItem","position":2,"name":"HCL, SO2 Absorption Efficiency"}]},{"@type":"WebSite","@id":"https:\/\/www.codel.co.uk\/#website","url":"https:\/\/www.codel.co.uk\/","name":"CODEL International LTD","description":"Codel International LTD -  Stack, Process Control and Tunnel Emission Monitors","publisher":{"@id":"https:\/\/www.codel.co.uk\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.codel.co.uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/www.codel.co.uk\/#organization","name":"CODEL International LTD","url":"https:\/\/www.codel.co.uk\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/www.codel.co.uk\/#\/schema\/logo\/image\/","url":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2021\/01\/CODEL-international-ltd-logo-1.png","contentUrl":"https:\/\/www.codel.co.uk\/wp-content\/uploads\/2021\/01\/CODEL-international-ltd-logo-1.png","width":300,"height":78,"caption":"CODEL International LTD"},"image":{"@id":"https:\/\/www.codel.co.uk\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.codel.co.uk\/#\/schema\/person\/317a00a7d8844a6cb1b6a2d04f99b6b6","name":"Teresa Shirley","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/af70882aa9eb7e65a9d99d0f6b31db5c45961b407110a3f9eb3cf7f09ecd4e53?s=96&d=mm&r=g","caption":"Teresa Shirley"},"sameAs":["https:\/\/www.codel.co.uk"],"url":"https:\/\/www.codel.co.uk\/ru\/author\/teresashirley\/"}]}},"_links":{"self":[{"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/posts\/4912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/comments?post=4912"}],"version-history":[{"count":38,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/posts\/4912\/revisions"}],"predecessor-version":[{"id":14711,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/posts\/4912\/revisions\/14711"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/media\/9244"}],"wp:attachment":[{"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/media?parent=4912"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/categories?post=4912"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.codel.co.uk\/ru\/wp-json\/wp\/v2\/tags?post=4912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}